Datasheets


As part of VibroSystM’s continuing process of product development and improvement, together with responsible product life-cycle management, certain products may be discontinued and gradually reach obsolescence, and no longer be available and/or supported. For advice on functional replacements and upgrades, or additional information, please contact us.


ZOOM System


VSM-AGMS
AGMS - Air gap monitoring system for hydroelectric generators
VSM-EWMS
EWMS - End winding monitoring system for turboelectric generators
VSM-ZOOM/HYDRO
ZOOM System for Hydroelectric Generators
VSM-ZOOM/TURBO
ZOOM System for Turbo-electric Generators
VSM-STDWG/M
ZOOM System Technical Drawings - Mining industries

Measuring Chain

Sensor

VSM-797S
VSM797S Piezoelectric Accelerometer (500 mV/g)
VSM-DCS400
DCS-400 sensor (0.5-2.5 mm)
VSM-FOA100E-10A
FOA-100E Fiber Optic Accelerometer (10 m/Class A 105°C)
VSM-FOA100E-10F
FOA-100E Fiber Optic Accelerometer (10 m/Class F 155°C)
VSM-FOA100E-20F
FOA-100E Fiber Optic Accelerometer (20 m/Class F 155°C)
VSM-FOA200-10A
FOA-200 Dual-Axis Fiber Optic Accelerometer (10 m/Class A 105°C)
VSM-FOA200-10F
FOA-200 Dual-Axis Fiber Optic Accelerometer (10 m/Class F 155°C)
VSM-FOT200-10
FOT-200 Fiber optic Temperature sensor (10 m)
VSM-MFP100
MFP-100 Magnetic field probe
VSM-MFP100/TURBO
MFP-100 Magnetic Flux Sensor for Turbo-Generators
VSM-PCS200ESB-6I
PCS-200 Capacitive proximeter (6 m integral cable/BOA/SMA/0.3-4.3/6.3 mm)
VSM-PCS202SB-6I
PCS-202 Capacitive Proximity Probe (6 m integral cable/BOA/SMA/0.3-2.3 mm)
VSM-PCS302
PCS-302 Capacitive Proximity Probe with built-in signal conditioner (0.3-2.3 mm)
VSM-PCS304
PCS-304 Capacitive Proximity Probe with built-in signal conditioner (0.5-4.5 mm)
VSM-PES103
PES-103 Eddy Current Proximity Sensor (0-3 mm)
VSM-PES106
PES-106 Eddy Current Proximity Sensor (0-6 mm)
VSM-PES110
PES-110 Eddy Current Proximity Sensor (0-10 mm)
VSM-PES302-30I
PES-302 Sealed Eddy Current Proximity Sensor (0-2 mm)
VSM-PES305-30I
PES-305 Sealed Eddy Current Proximity Sensor (0-5 mm)
VSM-SBV202P-6I
SBV-202P Capacitive sensor (6 m integral cable/0.3-2.3 mm)
VSM-SPES108
SPES-108 Underwater Eddy Current Proximity Sensor (0-8 mm)
VSM-SPES117
SPES-117 Underwater Eddy Current Proximity Sensor (0-17 mm)
VSM-SYNCHRO
Synchronization Probe
VSM-SYNCHRO/M
Synchronization sensor for mining industries
VSM-TWR200-_ (S,M or L)
TWR-200 ThermaWatch Rotor
VSM-TWR200-_ (S,M or L)
TWR-200 ThermaWatch Rotor for GMD - Mining industry
VSM-TWS200
TWS-200 Temperature Sensor
VSM-VM3AF
VM3 AIRFLOW air gap sensor (1-20 mm)
VSM-VM5AF
VM5 AIRFLOW air gap sensor (2-42 mm)
VSM-VM31-2/20
VM 3.1 air gap sensor (2-20 mm)
VSM-VM31-5/35
VM 3.1 air gap sensor (5-35 mm)
VSM-VM32-1/10-10
VM 3.2 air gap sensor (1-10 mm)
VSM-VM51
VM 5.1 air gap sensor (5-35/5-50 mm)
VSM-VM61
VM 6.1 air gap sensor - 0.5 m/1.6 ft Integral cable - (3-30 mm)
VSM-VMGMD
VM GMD air gap sensor (2-20/5-35 mm)
Cable-from sensor to conditioner

VSM-CBL-3AF-10S
Cable / Triaxial - SMA/SMA / (10 m/32.8 ft)
VSM-CBL-5AF-10S
Cable / Triaxial - SMA/SMA / (10 m/32.8 ft)
VSM-CBL-331-2/20-10
Cable / Triaxial – SMA/SMA / (10 m/32.8 ft)
VSM-CBL-331-2/20-15H
Cable / Triaxial – SMA/SMA / (15 m/49.2 ft)
VSM-CBL-331-5/35-10
Cable / Triaxial – SMA/SMA / (10 m/32.8 ft)
VSM-CBL-332-1/10-10
Cable / Triaxial – SMA/SMA / (10 m/32.8 ft)
VSM-CBL-351-5/50-10
Cable / Triaxial – SMA/SMA / (10 m/32.8 ft)
VSM-CBL-351-5/35-15H
Cable / Triaxial – SMA/SMA / (15 m/49.2 ft)
VSM-CBL-351-5/50-10H
Cable / Triaxial – SMA/SMA / (10 m/32.8 ft)
VSM-CBL-DCS400
Cable / Triaxial – SMA/SMA / (10 m/32.8 ft)
VSM-CBL-TWR200-30
TWR-200 ThermaWatch Rotor 30m Extension cable
VSM-CBL-TWR200-30
TWR-200 ThermaWatch Rotor 30m Extension cable for GMD
VSM-CBL-TWX-MFP-10
Cable / Twinax – MFP-100 – AWG 20 / (10 m/32.8 ft)
VSM-CBL-TWX-MFP-20
Cable / Twinax – MFP-100 – AWG 20 / (20 m/65.6 ft)
Conditioner

VSM-L33AF-10S-1/20
LIN-33AF-10S conditioner (1-20 mm)
VSM-L35AF-10S-2/42
LIN-35AF-10S conditioner (2-42 mm)
VSM-L302-PCS202S
LIN-302S-6I conditioner (0.3-2.3 mm) (SMA)
VSM-L302-SBV202P
LIN-302VP-6I conditioner (0.3-2.3 mm)
VSM-L304-PCS200ESB
LIN-304S-6I conditioner (0.3-4.3 mm)
VSM-L306-PCS200ESB
LIN-306S-6I conditioner (0.3-6.3 mm)
VSM-L331-2/20-10
LIN-331-10 conditioner (2-20 mm)
VSM-L331-2/20-15H
LIN-331-15H conditioner (2-20 mm)
VSM-L331-5/35-10
LIN-331-10S conditioner (5-35 mm)
VSM-L332-1/10-10
LIN-332-10S conditioner (1-10 mm)
VSM-L340-DCS400-10
LIN-340-10 conditioner (0.5-2.5 mm)
VSM-L351-5/35-15H
LIN-351-15H conditioner (5-35 mm)
VSM-L351-5/50-10
LIN-351-10S conditioner (5-50 mm)
VSM-L351-5/50-10H
LIN-351-10H conditioner (5-50 mm)
VSM-L361-3/30
LIN-361-7I conditioner (3-30 mm)
VSM-L361-5/50
LIN-361-7I conditioner (5-50 mm)
VSM-L50H-TWR200
TWR-200 ThermaWatch Rotor Signal conditioner (50Hz)
VSM-L60H-TWR200
TWR-200 ThermaWatch Rotor Signal conditioner (60Hz)
VSM-LGMD-TWR200
TWR-200 ThermaWatch Rotor Signal conditioner for GMD
VSM-MFC100
MFC-100 Magnetic field signal conditioner
VSM-PBOX-14-12-8
Protection box 14-12-8 for 2 LIN-300
VSM-PBOX-14-12-8-PS
Protection box 14-12-8 for 2 LIN-300 with power supply
VSM-PBOX-14-12-8-TB
Protection box 14-12-8 for 2 LIN-300 with terminal blocks
VSM-PBOX-TWR200
Protection box of the TWR-200 for GMD

Server & Software

ZOOM & License

VSM-Z74
ZOOM SOFTWARE SUITE Version 7.4

Acquisition & Protection

ZPU/SFA/CABINET

VSM-CAB/45
ZOOM monitoring cabinet 45U
VSM-CAB-AGMS/EWMS
Standard monitoring cabinet for energy industries
VSM-IM/ZPU-0/10V
“2-Ch.” Voltage Input Module (0 to 10 V)
VSM-IM/ZPU-0/5V
“2-Ch.” Voltage Input Module (0 to 5 V)
VSM-IM/ZPU-10/10V
“2-Ch.” Voltage Input Module (± 10 V)
VSM-IM/ZPU-100MVG-1
“2-Ch.” Vibration/Acceleration Input Module (ICP/100 mV/g) (1.13 g)
VSM-IM/ZPU-100MVG-5
“2-Ch.” Vibration/Acceleration Input Module (ICP/100 mV/g) (5.65 g)
VSM-IM/ZPU-2/-18V
“2-Ch.” Vibration / Proximity Input Module (-2 to -18 V)
VSM-IM/ZPU-4/20MA
“2-Ch.” Current Input Module (4 to 20 mA)
VSM-IM/ZPU-5/5V
“2-Ch.” Voltage Input Module (± 5 V)
VSM-IM/ZPU-500MVG
“2-Ch.” Vibration / Acceleration Input Module (ICP/500 mV/g)
VSM-IM/ZPU-AG
“2-Ch.” Air Gap Input Module
VSM-IM/ZPU-COMM
Communication module
VSM-IM/ZPU-CTRL
Control Module
VSM-IM/ZPU-FOA
“2-Ch.” Vibration / Acceleration Input Module (FOA)
VSM-IM/ZPU-P/A
“2-Ch.” Vibration / Combo Proximity & Acceleration Input Module
VSM-IM/ZPU-VEL
“2-Ch.” Vibration / Velocity Input Module (ICP / 3.94 mV/mm/s)
VSM-ZPU5000
ZPU-5000 Multi-channel processing instrumentation & monitoring/protection unit
VSM-SFA200
SFA-200 Stray Flux Analyser Unit
STATE-200

VSM-IIM/ST2-0/100MV
STATE-200 Isolated Input module (0 to 100 mV)
VSM-IIM/ST2-0/20MA
STATE-200 Isolated Input module (0 to 20 mA)
VSM-IIM/ST2-0/5VDC
STATE-200 Isolated Input module (0 to 5 Vdc)
VSM-IIM/ST2-0/50MV
STATE-200 Isolated Input module (0 to 50 mV)
VSM-IIM/ST2-10/10VD
STATE-200 Isolated Input module (-10 to 10 Vdc)
VSM-IIM/ST2-4/20MA
STATE-200 Isolated Input module (4 to 20 mA)
VSM-IIM/ST2-RTDCU
STATE-200 Isolated Input module (RTD CU10)
VSM-IIM/ST2-RTDPT
STATE-200 Isolated Input module (RTD PT100)
VSM-IIM/ST2-28/140VA
STATE-200 Isolated Input module (28 to 140 Vac)
VSM-IM/ST2-0/10VDC
STATE-200 Input module (0 to 10 Vdc)
VSM-IM/ST2-0/5VDC
STATE-200 Input module (0 to 5 Vdc)
VSM-IM/ST2-10/10VDC
STATE-200 Input module (-10 to 10 Vdc)
VSM-IM/ST2-4/20MA
STATE-200 Input module (4 to 20 mA)
VSM-IM/ST2-5/5VDC
STATE-200 Input module (-5 to 5 Vdc)
VSM-IM/ST2-DI
STATE-200 Input module (Dry Contact)
VSM-STATE200
STATE-200 Extension unit (16 inputs)

Installation

Cable & Connector

VSM-CBL-4CSZH22-M
Cable / 4 conductors shielded ’’Zero-Halogen’’ - AWG 22 (m)
VSM-CBL-4CSZH22-300M
Cable / 4 conductors shielded ’’Zero-Halogen’’ - AWG 22 (300 m spool)
VSM-CBL-M12SC4-100
Cable / M12 straight connector - 4 wires (100 m/ 328 ft)
VSM-M12FSC
M12 Mating straight connector (fem. type, unshielded)
VSM-M12FAC
M12 Mating angled connector (fem. type, unshielded)
VSM-M12FSSC
M12 Mating straight connector (fem. type, shielded)
VSM-M12FSAC
M12 Mating angled connector (fem. type, shielded)
Flange

VSM-FLG-9M12
Connectorized internal flange (M12 x 9)
VSM-FLG-12M12
Connectorized internal flange (M12 x 12)
VSM-FLG-W
Penetration Flange (welded) with safety cover

Services

Field services

VSM-MNT-CONTRACT
ZOOM System Remote Maintenance plan
VSM-SRV
Technical Support Services
VSM-SRV-CONTRACT
ZOOM System Maintenance Service Contract
Tests & Diagnostics services

VSM-RIS
Results Interpretation Services (RIS)
VSM-TDS-TDA
Data Analysis & Diagnostics Course
VSM-ZW-CONTRACTS
The ZOOMWatch Program
Factory services

VSM-FAT
Factory Acceptance Test
VSM-PACKAGING
Packaging specifications
Special services

VSM-ATEX/CONFORMITY
VibroSystM Safety Solution for Hazardous Locations

Manuals


VSM-MNL-797L
797L Piezoelectric Accelerometer Transducer – Installation Manual
VSM-MNL-797S
VSM797S Piezoelectric Accelerometer – Installation Manual
VSM-MNL-797V
797V Piezoelectric Velocity Sensor – Installation Manual
VSM-MNL-DCS400
DCS-400 Measuring Chains with LIN-340 Signal Conditioner
VSM-MNL-DM100
DM-100 Creep Detection System – Installation Manual
VSM-MNL-DMV100
DMV-100 Creep Detection System – Installation Manual
VSM‐MNL‐FLANGE
Penetration Flange with Connectorized Internal Flanges ‐ User’s Manual
VSM-MNL-FOA/U
FOA-Series Fiber Optic Accelerometers User’s Manual
VSM-MNL-MFM100
MFM-100 Magnetic Flux Measuring System – Installation Manual
VSM-MNL-MFP100/T
MFP-100 for Turbo Generator User’s Manual
VSM-MNL-PCS202SB
PCS-202SB Measuring Chains with LIN-300 Series Module – Front End Installation
VSM-MNL-PCS2ESL3
PCS-200ESB Measuring Chains with LIN-300 Series Module – Front End Installation
VSM-MNL-PCS302-304
Front End Installation of the PCS-302 and PCS-304 Measuring Chains
VSM-MNL-PES103
PES-103 Eddy Current Proximity Sensor User’s Manual
VSM-MNL-PES106
PES-106 Eddy Current Proximity Sensor User’s Manual
VSM-MNL-PES110
PES-110 Eddy Current Proximity Sensor User’s Manual
VSM-MNL-PES302
PES-302 User’s Manual
VSM-MNL-PES305
PES-305 User’s Manual
VSM-MNL-SBV202P
SBV-202P Stator Bar Vibration Measuring Chain User’s Manual
VSM-MNL-SBV/L
SBV-202 with LIN-302V – Installation Manual
VSM-MNL-SETZPUSTD
Setting the ZPU-5000 unit in standalone mode Procedure (with ZAC Plugin)
VSM-MNL-SETZPU/ZM
ZOOM Configuration for ZPU-5000 Standalone (c/w: Modbus) User’s Manual
VSM-MNL-SPES108
SPES-108 Measuring Chains – User’s Manual
VSM-MNL-SPES117
SPES-117 Submersible Proximity Probe – User’s Manual
VSM-MNL-ST200
The State-200 Extension – Installation and Operation Manual
VSM-MNL-SYNCHRO
Synchronization Probe User Manual
VSM-MNL-TWR100/U
TWR-100 ThermaWatch Rotor – Fast-Response Non-Contact Rotor Pole Temperature Monitoring – User’s Manual
VSM-MNL-VM31/U
VM3.12 Capacitive Air Gap Measuring Chains User’s Manual
VSM-MNL-VM32/U
VM3.2 Capacitive Air Gap Measuring Chains User’s Manual
VSM-MNL-VM5/U
VM5.1 Capacitive Air Gap Measuring Chains User’s Manual
VSM-MNL-VM6/U
VM6.1 Capacitive Air Gap Measuring Chains User’s Manual
VSM-MNL-WKGATE
Linear Displacement Transducer – Installation Manual
VSM-MNL-XPSP224
XPSP-224 External Power Supply Panel for Measuring Chains User’s Manual
VSM-MNL-Z73
ZOOM Software Suite Version 7.3 – Installation Guide
VSM-MNL-Z74
ZOOM Software Suite Version 7.4 – Installation Guide
VSM-MNL-ZPU/Z72
ZPU-5000 Acquisition Unit User’s Manual for ZOOM Version 7.2
VSM-MNL-ZPU/Z73
ZPU-5000 Acquisition Unit User’s Manual for ZOOM Version 7.3
VSM-MNL-ZPU/Z74
ZPU-5000 Acquisition Unit User’s Manual for ZOOM Version 7.4

Brochures


Complete Monitoring Solutions & Diagnostics services for the Hydro Industry
Complete Monitoring Solutions & Diagnostics services for the Turbo Industry
Data Analysis & Diagnostics Course for the Hydro Industry
Data Analysis & Diagnostics Course for the Mining Industry
Data Analysis & Diagnostics Course for the Turbo Industry

Application Notes


Mechanical Tolerance Guidelines for Hydroelectric Generators
ZOOM Software Measurement and Graph Types
Air Gap Results Introduction – Pole vs. Time-reference Method
Techniques to Verify Rotor Stability Using Air Gap Measurements
Overview of Typical Factors Affecting the Air Gap of a Hydrogenerator
Understanding ZOOM Shaft Orbit Graph
Stator Sagging on Bulb Generators
Evaluating Relative Thermal Expansion of Stator Using Air Gap Measurements
Technique for Detecting Rotor Rim Vibration

Case Studies


Detecting and Diagnosing a Rotor Design Weakness on New Hydrogenerators
Shortcomings of Conventional Vibration Monitoring
Alternative to Generator Shutdown During Peak Season
Rotor Pole Short Circuit & Gear Teeth Monitoring

Papers


Avoiding major damage on a new hydrogenerator by monitoring air gap at Igarapava H.E.P.P.
End-winding vibration in large rotating machines
Air gap monitoring system key element to correctly diagnose generator problems
On-line monitoring systems as used by Electronorte at the Tucurui II & Coaracy Nunes power plants
On-line vibration and temperature direct measurement on high voltage devices using fiber optic sensor technology
Air gap monitoring key element to correctly identify source of shaft vibration
Air gap monitoring key element to avoid unnecessary and costly repairs
Tidal power plant bulb unit management through air gap monitoring
Rotor shape vs. rotor field pole shorted turns
On-line condition monitoring solutions for Jirau & Santo Antônio hydroelectric projects
A novel approach to partial discharge monitoring
End-winding vibration monitoring: pivotal in preventing major damage on a large turbo-generator
Concrete Expansion – R.H. Saunders GS Innovative Structural Rehabilitation & Mitigation Effectiveness